Sineson
SINESON is an innovative radiofrequency (RF) system that combines monopolar RF RET and CET, as well as multipolar RF, providing effective treatments for both aesthetics and rehabilitation. With high frequency technology (448 kHz), it allows controlled and deep treatments, stimulating cell regeneration, collagen and elastin production, in addition to improving blood and lymphatic circulation.
Using high-frequency radiofrequency, SINESON generates an electric current that creates a magnetic field, promoting controlled heating of the deepest layers of the skin. This process reaches the dermis, hypodermis, fascia and muscles, resulting in significant therapeutic effects, both in aesthetics and in muscle and joint recovery.


Most common applications
Combats sagging, fine lines and wrinkles by stimulating the production of collagen and elastin.
Reduction of localized fat, cellulite, sagging and skin rejuvenation.
Muscle recovery, pain relief, and treatment of muscle and joint injuries.
Promoting relaxation and stress relief.

The deep heat of resistive electrical transfer technology is generated due to the electromagnetic activity that occurs between the uninsulated conductive electrode and the plate.
Monopolar RF RET
It is used for local tissue treatment in specific areas such as visceral fat. It improves joint pain, visceral fat, subcutaneous fat, cellulite treatment, etc.

Capacity Electric Transfer (CET) technology is a method that can be applied to high-power devices, where the ceramic surface that comes into contact with the patient's skin is wrapped with an insulator, and the contact plate is made through a non-insulated metal plate.
Vigorous electronic activity occurs around the ceramic in contact with the skin, generating bioheat. Therefore, it is effective in managing subcutaneous fat close to the surface of the skin tissue.
Monopolar RF CET
It is also used to treat pain in joint areas where the muscles are not dense, such as cold hands and feet, degenerative arthritis and frozen shoulder.
This is effective for facial care, hair loss care, subcutaneous fat care, etc.

Because an RF handpiece has multiple electrodes, energy flows along a short path between the electrodes, so high-frequency thermal energy is focused to the target depth.
Applied to intensive local treatment and in areas with many curves, such as the face, neck and décolleté.
The deep heat of resistive electrical transfer technology is generated due to the electromagnetic activity that occurs between the uninsulated conductive electrode and the plate.
Monopolar RF RET
It is used for local tissue treatment in specific areas such as visceral fat. It improves joint pain, visceral fat, subcutaneous fat, cellulite treatment, etc.
Capacity Electric Transfer (CET) technology is a method that can be applied to high-power devices, where the ceramic surface that comes into contact with the patient's skin is wrapped with an insulator, and the contact plate is made through a non-insulated metal plate.
Vigorous electronic activity occurs around the ceramic in contact with the skin, generating bioheat. Therefore, it is effective in managing subcutaneous fat close to the surface of the skin tissue.
Monopolar RF CET
It is also used to treat pain in joint areas where the muscles are not dense, such as cold hands and feet, degenerative arthritis and frozen shoulder.
This is effective for facial care, hair loss care, subcutaneous fat care, etc.
Because an RF handpiece has multiple electrodes, energy flows along a short path between the electrodes, so high-frequency thermal energy is focused to the target depth.
Applied to intensive local treatment and in areas with many curves, such as the face, neck and décolleté.



Main mechanisms and benefits
Heating the deeper layers of the skin stimulates the synthesis of collagen and elastin, which contributes to improving the firmness and elasticity of the skin. This effect is especially sought after in facial rejuvenation and body sagging treatments.
Increasing the temperature in the deepest layers of the tissues accelerates blood and lymphatic circulation, promoting cellular oxygenation and the elimination of toxins. This is very useful in combating cellulite and treating fluid retention and in expanding blood vessels, increasing blood flow by 4 to 5 times.
Sineson has a biostimulant effect, accelerating cellular metabolism. It can be useful in reducing localized fat, since the increase in metabolism favors fat burning. In addition, it promotes the elimination of dead cells, aiding in cellular regeneration and being effective in cases of scars and stretch marks.
In physiotherapy, Sineson is used to accelerate muscle recovery and reduce pain and inflammation. The deep heat improves joint mobility and relieves pain in muscles and ligaments. This process also contributes to increased oxygen and tissue nutrition.
The application of Sineson in athletes and people with muscle or joint injuries helps to speed up recovery by increasing blood circulation, reducing muscle tension and increasing oxygenation in the tissues. The treatment is painless, has no side effects and provides immediate results .
Sineson technology generates thermal energy, promoting an increase in body temperature between 5 and 7°C, which stimulates metabolism and promotes tissue recovery. This effect also stimulates the immune system, providing benefits for health and general well-being.
Sineson is considered a safe treatment, as its technology was developed to act in a controlled and non-invasive manner. The temperature reached during the treatment is carefully monitored, ensuring that the procedure is comfortable for the patient. Sessions can last from 20 to 60 minutes, depending on the area treated, and there is no need for recovery after treatment.
In aesthetics, this equipment has a great reputation due to its visible results, being used by beauticians to offer treatments ranging from facials to body treatments, always with a focus on improving skin quality, toning and body definition. The results are often noticed immediately after the first session, and with consecutive treatments, the effect is even longer lasting.
Tools
With the tip of SINESTON, you can relax the nodules in the muscles before using the RET electrode, relax the muscles with SINESTON.
High-power RF generates heat immediately and focuses the heat on the patient's contact area.


TECHNICAL SPECIFICATIONS
Energy Type – Radio Frequency
Monopolar Frequency – MAX 324W
Dimensions - W415 x D350 x H200mm
Weight – 18Kg
Application
Fill out the form below and request your personalized quote.